Gauges and displays on the sterilizer should be monitored for cycle time, temperature, and pressure. NOTEAside from chemical indicators, physical parameters should also be checked by you and your staff. Internal chemical indicators: These should be placed inside each package (next to the instruments) to ensure the sterilizing agent reached inside it. There are two types of chemical indicators:Įxternal chemical indicators: These change color when a specific parameter is reached, and should be applied to the outside of sterilization packages. It’s recommended that your office includes chemical indicators in each load. However, incorrect readings can help identify a problem with the sterilization cycle. They let you know a package has been placed through a sterilization cycle.Ĭorrect readings don’t prove that sterilization occurred. It’s a good practice to place the strips in a different location of the sterilizer each week to help identify any “cold spots.” Chemical Indicators: Tests for procedural errors or inadequate physical conditions (for sterilization)Ĭhemical indicators help assess physical conditions, and identify procedural errors. If there are no instructions, place the spore test strip within a wrapped set of instruments in the most difficult area to be sterilized-normally the lower front area of the sterilizer.

dental steri-dent dry heat sterilizer 300

(Note that lot number and expiration date are printed on each glassine.) The glassine-bound spore strips should be placed according to the sterilizer manufacturer’s instructions. (Glassine paper is permeable to sterilant, but resistant to moisture and air at ambient temperature and pressure.) How should spore testing be conducted? This paper is packaged in a peel-open, glassine-paper pouch.

dental steri-dent dry heat sterilizer 300

Specific spores (Geobacillus stearothermophilus for steam/chemical sterilizers, and Bacillus atrophaeus for dry heat sterilizers) are inoculated onto strips of specialized filter paper. How does spore testing work?īiological indicators impregnated with highly-resistant, nonpathogenic bacterial spores test a sterilizer’s function.

DENTAL STERI DENT DRY HEAT STERILIZER 300 CODE

Texas Administrative Code states that “sterilization equipment and its adequacy shall be tested and verified in accord with American Dental Association (ADA) recommendations.”ĪDA recommends that dental offices monitor sterilizers at least weekly with biological indicators. Biological Monitoring (Spore Testing): Tests for Sterilizationīiological monitoring-or spore testing-is the standard for assuring proper sterilization of dental instruments. We’ll cover two tools you should be using in your office to monitor your sterilizer, and give you a few related and important tips. These components need to be in place to evaluate the conditions of the sterilizing process in your office, and your sterilizer’s effectiveness. Regular sterilizer monitoring-when properly implemented-is an important part of an effective infection control program in a dental office.īut proper monitoring requires you and your team to understand and correctly implement the factors (a combination of process parameters) leading to successful sterilization. CPAC Sterilizers also have automatic timers with heat "hold" capability for continuous use in a busy practice.Why monitor your sterilizer? To verify infection control, of course. Utility trays can be sterilized with lids on and stored without contamination.

dental steri-dent dry heat sterilizer 300

Stainless steel construction means no rust - ever!ĬPAC Dry Heat Sterilizers require no routine cleaning. CPAC products feature a rapid-start heating element for fast operation. Plus, they can be used to dry wet packs or as a back-up sterilizer in your practice - the perfect complement to an autoclave.ĭry heat sterilization works without pressure, steam, or chemicals, which increases safety.

DENTAL STERI DENT DRY HEAT STERILIZER 300 MANUAL

  • Tray size: 10"W x 6.24"H > Outside dimensions: 15.5"W x 10.5"W x 9.5" deep > Shipping weight: 17lbs > Power consumption: 500 Watts > up to 60 minutes minutes cycle > Manual controlledĬPAC Dry Heat Sterilizers kill bacteria without moisture and will not dull sharp instruments.
  • This sterilizer is an FDA > Approved sterilizer
  • The outside dimensions for this dry heat sterilizer is (W) 15.5" (H)10.5" (D)9.5" 500watts.